INSTALLATION REQUIREMENTS

LOCATION REQUIREMENTS

·
Empty the water tank before turn on the unit.
·
During the operation, keep unit closed to the door
and windows closed to save energy.
·
Make sure no block at air inlet and outlet.
·
Put the unit is stably laid on as the following photo.
(At least 20cm from the front/back or the left/right,
and at least 50cm from the top.)
REQUIRED GROUNDING METHOD
This dehumidifier must be grounded. The dehumidifier is
equipped with a power supply cord that has a grounding
plug. The power supply cord must be plugged into a mating,
grounded outlet, and grounded in accordance with all local
codes and ordinances.
220V
16 Amp

ELECTRICAL REQUIREMENTS

WARNING
Electrical Shock Hazard
Plug into a grounded outlet only.
Do not remove the ground contacts from the power
cord plug.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire or eletrical shock.
POWER SUPPLY CORD
Wiring Requirements
·
220 Volt, 50Hz, 16-amp fused grounded outlet
·
The use of a time-delay fuse or time-delay circuit breaker
is recommended.
·
Use a dedicated circuit only .
NOTE: Do not operate any other electrical
appliances on this circuit or you may trip the circuit
breaker/fuse.
If this power supply cord is damaged, it cannot be repaired. It
must be replaced with a cord from the product manufacturer.