5.
Scope of delivery
Quantity
1
1
6.
Dimensions
7.
Installation example
8.
Installation
8.1
Hempen both sides and screw together.
A: Model with internal thread
B: Model with screw connection
!
Caution!
It is essential to check the direction of flow when installing (see the arrow mark on the
valve).
9.
Function
Trigger water flow
9.1
Pressing the pressure cap (a) triggers water flow.
9.2
The water flow stops automatically according to the flow duration set. The flow time can
be set from 1 s to 50 s.
☞
When the pressure cap is activated, the emergence of a few drops of water from the
fitting is a functional characteristic.
10. Adjusting flow duration
Blade width 3 mm
11. Removing the functional part
Description
Self-closing straight-way valve
Installation and operating instructions
5