10 Technical specifi cati ons
Supply voltage
Mains voltage:
Low voltage:
Power consumpti on
Terminal resistance of the safety contact edges
nominal value
upper switching point
lower switching point
Nominal current DC
Nominal current AC
Mech life-ti me
Switching off delay (response ti me)
Switching on delay
protecti on
Housing
Dimensions (HxWxD)
Housing
Housing incl cable clamps
Protecti on class
Weight
460 g
Temperature range
Connecti on cable cross-secti on
single- or fi ne-stranded cable 0,75-1,5 mm
Certi fi cati ons
ELMON inducti ve 74-312 EN ISO 13849-1:2015 Category 3 PL d
Electronics
Electromechanics
Output unit (relay)
signal transmitt er
(Example SENTIR mat)
Safety device acc to DIN EN 12978
All voltages connected to the switching unit must be safely
isolated!
U
230 V AC 50/60 Hz
mains
U
24 V AC/DC ±10 %
E
P
3 VA
max
Stati onary
Travelling
contact edge
contact edge
R
= 8,2 kΩ
nom
R
> 12 kΩ
AO
R
< 5 kΩ
AU
2 A
24 V DC
2 A
30 V AC
>10
actuati ons
6
Stati onary
contact edge
< 10 ms
500 ms (Power on 700 ms)
2A ti me lag (glass tube 5x20)
Polystyrene with transparent cover
80 x 120 x 55 mm
102 x 120 x 55 mm
IP65
-20°C to +55°C
2
MTTFD 81 years, DC 95 %, PFHD 6,62E-08 1/h
MTTFD 81 years, DC 95 %, PFHD 6,62E-08 1/h
MTTFD 598 years, DC 99 %
MTTFD 380 years, DC 99%
(B10D 2000000, Nop 52560)
MTTFD 380 years, DC 90%
(B10D 2000000, Nop 52560)
= 8,2 kΩ
> 20 kΩ
< 2,5 kΩ
Travelling
contact edge
< 30 ms
EC type-examinati on no.:
44 205 13 031832
Test report no.:
3525 3024