INSTALLATION
Installation must be carried out by qualified personnel in compliance with
local, national and European regulations.
4.1
After unpacking the hood, remove any polystyrene protections and take
off the protective film (F). Do not use tools that could damage the
surfaces. If any glue residue remains on the surface, remove it with a
suitable, non-corrosive solvent.
Lift the hood, (consult the table in the technical data for the weight) and
position it above the oven. Use the specific screws to fix the hood on the
upper part of the oven cover, connecting the oven vapour vent to the
hood conveyor.
The pipe to connect to the exhaust fan must be supplied by the installer
after checking the specific structure of the room.
4.2 EQUIPMENT HOOK-UP
4.2.1 Electrical connection
The hood is supplied with a power cable not provided with a plug. When
connecting the appliance electrically, a differential magnetothermic
switch with suitable characteristics must be interposed, with an opening
distance between the contacts of at least 3 mm. To connect the hood
electrically it is essential to proceed in the following manner:
HOOD POSITIONING