en
14
Character
L
pA
L
wA
L
pCpeak
K...
h,D
For your safety.
Read all safety warnings and all
WARNING
instructions. Failure to follow the
warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future reference.
Do not use this power tool before you have thor-
oughly read and completely understood this
Instruction Manual and the enclosed "General
Safety Instructions" (document number
3 41 30 054 06 1). The documents mentioned should be
kept for later use and enclosed with the power tool,
should it be passed on or sold.
Please also observe the relevant national industrial safety
regulations.
Intended use of the power tool:
hand-held drill for drilling in metal, wood, plastic, ceram-
ics, and for tapping in weather-protected environments
using the application tools and accessories recommended
by FEIN.
Special safety instructions.
Use auxiliary handle(s), if supplied with the tool. Loss of
control can cause personal injury.
Hold power tool by the insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord. Cutting acces-
sory contacting a "live" wire may make exposed metal
parts of the power tool "live" and could give the opera-
tor an electric shock.
Beware of any concealed electric cables, gas or water
conduits. Check the working area before commencing
work, e. g. with a metal detector.
Secure the work piece firmly. A work piece that is
gripped tightly in a clamping device or vice, is more
secure than if held by hand.
Hold the power tool firmly. High reaction torque can
briefly occur.
Unit of measure-
Unit of measure-
ment, international
ment, national
mm
mm
mm
mm
kg
kg
dB
dB
dB
dB
dB
dB
2
m/s
m/s
2
m/s
m/s
m, s, kg, A, mm, V,
m, s, kg, A, mm, V,
W, Hz, N, °C, dB,
W, Hz, N, °C, dB,
2
min, m/s
min, m/s
Explanation
Tap
d1 = Clamping range of drill chuck
d2 = Shank size of drilling shaft
d3 = Collar diameter
Weight according to EPTA-Procedure 01
Sound pressure level
Sound power level
Peak sound pressure level
Uncertainty
2
Vibrational emission value according to EN 60745
(vector sum of three directions)
2
Mean vibrational value for drilling in metal
Basic and derived units of measurement from the
international system of units SI.
2
Do not direct the power tool against yourself, other per-
sons or animals. Danger of injury from sharp or hot
application tools.
Do not rivet or screw any name-plates or signs onto the
power tool. If the insulation is damaged, protection
against an electric shock will be ineffective. Adhesive
labels are recommended.
Do not use accessories which are not specifically
designed and recommended by the power tool manufac-
turer. Safe operation is not ensured merely because an
accessory fits your power tool.
Clean the ventilation openings on the power tool at regu-
lar intervals using non-metal tools. The blower of the
motor draws dust into the housing. An excessive accu-
mulation of metallic dust can cause an electrical hazard.
Before putting into operation, check the mains connec-
tion and the mains plug for damage.
Recommendation: The tool should always be supplied
with power via a residual current device (RCD) with a
rated current of 30 mA or less.
Hand/arm vibrations
The vibration emission level given in this information
sheet has been measured in accordance with a standard-
ised test given in EN 60745 and may be used to compare
one tool with another. It may be used for a preliminary
assessment of exposure.
The declared vibration emission level represents the
main applications of the tool. However, if the tool is used
for different applications, with different accessories or
poorly maintained, the vibration emission may differ.
This may significantly increase the exposure level over
the total working period.
An estimation of the level of exposure to vibration
should also take into account the times when the tool is
switched off or when it is running but not actually doing
the job. This may significantly reduce the exposure level
over the total working period.