switched off) the "clean air" function is activated. This
function switches the appliance on for ten minutes every
hour at the first speed. As soon as this function is acti-
vated the motor star ts up at the first speed for ten
minutes, During this time key F and key C must flash at
the same time.
After ten minutes the motor switches off and the LED of
key F remains switched on with a fixed light until the
motor starts up again at the first speed after fifty min-
utes and keys F and C start to flash again for ten min-
utes and so on.
By pressing any key for the exclusion of the hood light
the hood will return immediately to its normal functioning
(e.g. if key D is pressed the "clean air" function is deac-
tivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
(*) The "automatic stop timer" delays stopping of the
hood, which will continue functioning for 15 minutes at
the operating speed set at the time this function is
activated.
• Active carbon/grease filter saturation:
- When button A flashes at a frequency of 2 seconds,
the grease filters must be cleaned.
- When button A flashes at a frequency of 0.5 seconds,
the carbon filters must be replaced.
After the clean filter has been replaced, the electronic
memor y m ust be reset by pressing button A for
approximately 5 seconds, until the light on the button
stops flashing.
THE
MANUFACTURER
DECLINES
ALL
RESPONSIBILITY FOR EVENTUAL DAMAGES
CAUSED BY BREACHING THE ABOVE WARNINGS.
- 21 -