POSSIBLE FIXING POINTS ON A FLAT ROOF

Notes:
Each single GV adjustable support for flat roofs must be secured against slipping and overturning due to the wind, with at least two
diameter 12 screws (to be chosen as required): directly on the roof structure, making sure to seal the holes to prevent water from
entering, or on a substructure arranged by the customer.
Example of a substructure: cement slabs, iron/cast iron plates, steel I-beams, cement slabs plus anchoring, etc.
Important: The substructure, arranged by the customer, must be able to absorb the wind load on the collectors and be fixed in such
a way so as not to damage the roof.
NOTE: In case of installation in particular situations, a prior static/structural study is advisable. To make the fixing system even more
stable, the number of GV support kits can be increased.
• = RECOMMENDED FIXING POINTS IN
• = RECOMMENDED FIXING POINTS IN
NORMAL LOAD CONDITIONS
NORMAL LOAD CONDITIONS
450
1300
100

INSTRUCTIONS FOR FLAT ROOF INSTALLATION

Notes:
The GV kit is applied with the sloping roof TIV kits to obtain the required inclination. The GV kit is fitted after completing points 1 and
2 for fitting the kits for sloping roof.
GV
box kit
x 2
(TCEI M8x75)
x 2
(TCEI M12x20)
28
EN
1200
1200
1200
100
1795
x 1
Cod. 3540S892 - 01/2010 (Rev. 00)
X = RECOMMENDED FIXING POINTS IN
X = RECOMMENDED FIXING POINTS IN
HIGH LOAD CONDITIONS
HIGH LOAD CONDITIONS
1200
1200
ø12.5
VF
1395
450
245
705
245