5. Use adjustable wrench to remove LP hose regulator from
brass elbow. Use adjustable wrench to remove brass elbow.
A
B
C
D
A. Manifold
B. Brass elbow
C. Rear of Power™ burner
D. Gas pressure regulator/hose assembly
6. Apply pipe sealant to the threads of the brass connector. Use
pipe thread sealant that is certified for use with LP gas.
7. Use adjustable wrench to install brass connector (supplied) to
manifold fitting.
NOTE: The arrow on the regulator must be pointing toward
the brass connector.
8. Use pipe wrench to install the convertible regulator. Brass
cap will be facing up when tight.
A
A. Brass connector
B. Convertible regulator
9. To set the appliance regulator for LP gas, use adjustable
wrench to remove the brass cap on the convertible regulator.
10. Examine the stem on the brass cap. The letters "NAT" should
be showing on the end of the plastic stem farthest away from
the brass cap.
16
B
11. Remove stem from cap, turn it over and snap stem back into
the cap so the letters "LP" are at the end of the stem farthest
away from the brass cap.
12. Use adjustable wrench to reinstall cap onto regulator.
Make Power™ Burner Connections
Connect Local LP Gas Supply
1. Use pipe wrench to connect certified ½" (1.3 cm) gas supply
pipe to inlet side of regulator from Fixed LP gas supply
according to local codes requirements. Use pipe thread
sealant that is certified for use with LP gas at connections
where required. There must be a certified manual shutoff
valve in the gas supply line near the Power™ burner for easy
access.
2. Turn on the gas supply to the Power™ burner.
3. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leaks found.
Record Conversion
In the last page of the Use and Care Guide, write "Converted to
Local LP Gas Supply." Also record the conversion date and the
technician/company that performed the conversion.
Conversion from LP Gas to Natural Gas
Installation of the regulator
1. Turn off the main gas supply valve.
2. Unplug Power™ burner or disconnect power.
3. Disconnect 20 lb LP gas fuel tank (if present).
4. Turn off all burner control valves.
5. Use adjustable wrench to remove LP hose regulator from
brass elbow. Use adjustable wrench to remove brass elbow.
A
B
C
D
A. Manifold
B. Brass elbow
C. Rear of Power™ burner
D. Gas pressure regulator/hose assembly