PURITY C AC
The PURITY C1000 AC filter system has a filter capacity of 10,000 litres (2641 US gallons),
regardless of carbonate hardness and the by-pass set. All intake water is filtered (Chapter 4.2).
Substance reduction
This system has been tested according to NSF/ANSI 42 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentra-
tion less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42.
Test data for PURITY C1000 AC
Substance
Guidelines
Chlorine
NSF/ANSI 42
Substance
Particulate, class 1 particles
0.5 to < 1µm
Testing conditions
Flow rate PURITY C 1000 AC:
Pressure:
Temperature:
Average
Maximum Effluent
Influent
Concentration
Concentration
2.1 mg/l
0.05 mg/l
Influent challenge
concentration
At least 10.000 particles/ml
0.79 GPM
60 +/– 3 psi
20 +/– 3 °C
Minimum
Average
Percent
Effluent
Removal
Concentration
97.4 %
0.05 mg/l
Reduction requirement
≥ 85 %
Average
Percent
Removal
97.6 %
Overall percent reduction
98.90 %