Changing The Filter Cartridge - Vivreau PURITY C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.2 By-pass setting for and capacity of PURITY C 0 – 70 % filter heads
Determine the carbonate hardness (for PURITY C filter cartridges) by performing the
VIVREAU carbonate hardness test. Alternatively, your local water supplier will be able to
provide information on the local water hardness.
Determine the by-pass setting and capacity in line with the application and the carbonate
hardness identified using the by-pass and capacity table (pages 3–9).
Then turn the by-pass setting
To ensure precise and continuous control of the degree of filter cartridge exhaustion, it is
recommended to install the VIVREAU FlowMeter 10 – 100 A.
Note: With PURITY C AC and PURITY C Finest filter cartridges, all of the intake water is filtered.
The filter cartridge can be used with filter heads that have a variable or fixed by-pass. The by-pass
that may be set in the filter head is not taken into account.
4.3 Inserting the filter cartridge
Pull the flap of the protective cap
E
Note the next exchange date in the date field on the filter cartridge
Insert the filter cartridge
F
Caution: The filter cartridge can only be inserted when the locking handle is open.
!
Make sure that the filter cartridge is positioned correctly.
Turn the locking handle
4.4 Commissioning
Open the water intake and switch on the terminal equipment's power supply.
G
Operate the flush valve
without bubbles. At least two empty filter cartridge volumes must be flushed ( Chapter 9).
H
Note: When bleeding/flushing, catch water emerging from the flush hose
appropriate container.
Check system for any leaks.
5 Changing the filter cartridge
The PURITY C filter cartridge must be replaced once the stated capacity has been reached
(see Chapter 6), in accordance with manufacturer´s specifications or no later than 12 months after
commissioning, whichever occurs first.
Caution: When changing a filter cartridge, examine all remaining parts carefully! Faulty parts
!
must be exchanged and contaminated parts should be cleaned. Read the operating and safety infor-
mation (Chapter 3) before changing the cartridge. After storage and transport below 0 °C (32 °F) the
product must be stored in the open original packaging for at least 24 hours before it is commissioned
at the stated ambient temperatures (Chapter 9) for operation.
Note: When the locking handle is open, the water supply to the cartridge is interrupted and short-
circuit operation with direct water flow from the water inlet
(if necessary, close the water intake and switch off the power supply to the terminal equipment).
Open locking handle
Activate the flush valve
Remove exhausted filter cartridge
tridge. Note: The filter cartridge can be pivoted by 90 ° in the wall mounting bracket for easy removal.
Perform the steps described at 4.3 and 4.4.
to the identified value.
10
upwards and remove the protective cap.
7
in the filter head
6
until you feel it engage.
2
and flush the filter system until the filtered water runs clear and
8
.
2
and depressurise the system.
8
from the filter head
6
in a vertical position.
1
to the water outlet
4
, bearing in mind the weight of the car-
1
.
6
in an
9
is possible
3
13
EN