7.2-C Resetting Maximum Output Temperature of Valve
1) Turn off the volume control
2) Return the handle position to the High Temp Over-Ride Position.
3) Remove the Handle Assembly (Figure 7.1)
4) Rotate the cartridge stem clockwise by 1/8 of a turn.
5) Reinstall the Handle Assembly (Figure 7.3)
6) Check the valve maximum output temperature by following 7.2-B. If the temperature is still above your desired
temperature, repeat steps 1 through 5.
7.3
Reinstall thermostatic handle assembly.
A.
Turn off the volume control handle clockwise.
B.
Reinstall temperature selector handle. The temperature
limit over-ride button should align the gun sight on limit
stop.
C.
Install the screw in the thermostatic handle and
tighten it by hex wrench (supplied), then attach
the handle cap.
6
Over-ride button is in line with the gun sight.
© 2008 Danze, Inc. All rights reserved.
®