7.2. Harrison address conversion to switch settings
The address used is converted to the address selected in the Harrison curtain motor using the
table below.
switch 1 2 3 4
H H H H
A
0 1 1 0
B
0 1 1 1
C
0 1 0 0
D
0 1 0 1
E
1 0 0 0
F
1 0 0 1
G
1 0 1 0
H
1 0 1 1
I
1 1 1 0
J
1 1 1 1
K
1 1 0 0
L
1 1 0 1
M
0 0 0 0
N
0 0 0 1
O
0 0 1 0
P
0 0 1 1
H H H H = House code
X X X X = device code
Switch position in the motor:
Up
= 1
Middle = not used!!!!
Down = 0
Examples:
If you assign the address E7 (1000 0110) to the curtain motor then set the switches to: 1=up,
2=down, 3=down, 4=down, 5=down, 6=up, 7=up, 8=down
If you assign the address A2 (0110 0001) to the curtain motor then set the switches to: 1=down,
2=up, 3=up, 4=down, 5=down, 6=down, 7=down, 8=up
Copyright 2011-2017, RFXCOM
5 6 7 8
X X X X
1
0 0 0 0
2
0 0 0 1
3
0 0 1 0
4
0 0 1 1
5
0 1 0 0
6
0 1 0 1
7
0 1 1 0
8
0 1 1 1
9
1 0 0 0
10
1 0 0 1
11
1 0 1 0
12
1 0 1 1
13
1 1 0 0
14
1 1 0 1
15
1 1 1 0
16
1 1 1 1
RFXtrx FR Version 5.33