Mounting instructions for installers and
appliance fitters
Important: Read these instructions thoroughly before
installing the appliance. Determine the precise position in
the salon with the salon owner and the installation
specialist.
The wash unit is intended for operation in clean and
dry rooms at normal room temperature.
In the water supply system only original components
supplied by the manufacturer must be used.
The wash unit must only be connected to a water
supply where the supply pressure does not exceed
20 bar (20 MP a).
The new set of hoses supplied with the unit must be
used. Old hoses must not be used.
Observe minimum power socket spacing specified in
DIN VDE 0100 and VDE 0100 Part 701.
Ensure that the height of the drain and installation
shaft is correct.
1.
The water supply pipes to the wash unit must be
equipped with an "Aqua-Stop" system.
2.
Install the supply water and waste water lines as
shown in Fig. 2.
6.
Make sure that pipes/pressure hoses are parallel.
Connect the unit. Fit 40 mm dia. waste water pipe
and R ½" pressure lines with stop taps between the
wall and unit. Prevent the stop valves from
turning while they are being screwed on.
Connect the waste water hose to the siphon using a
seal and union nut. Insert the waste water hose at
least 3 to 4 cm into the siphon. Connect the drain
bushing to the waste water hose using a hose clamp.
7.
Close the mixing tap. Open the stop valve and check
for leaks with the mixing tap closed. Check the mixed
water. The hot water and cold water supply must
correspond to the coloured symbols on the mixing
tap.
8.
Check the pressure of the unit with 8 bar water
pressure. Then set the pressure to 3 to 5 bar. On
completion of the installation work, always rinse out
the water pipes. A central regulating tap is required if
more than one unit is installed. This tap must be
easily accessible from the salon.
9.
These mounting instructions apply to the
connection of one unit. If more than one unit is to
be installed, the pipe cross section must be increased
accordingly.
Comfort
MO W+R
GB
Mounting instructions for installers and
appliance fitters
Important: If the water pressure is above 5 bar, it must be
regulated by a pressure reduction valve. Since a pressure
reduction valve is used for boilers, such a valve can be fitted
along the common water supply line.
Note for salon owners:
The connections described under points 1 to 2 and 6 to 9 must
be performed by the installer. The installer is responsible for
any problems that may occur. The manufacturer of the unit
shall not accept warranty claims for this work.
3. Prepare the shampoo unit for installation:
- Remove inspection door (5): Grasp the opening and pull
back, then lift out downwards.
- Plug in power cable.
- Extend leg rest to final position.
- Remove cover at the bottom of the chair (7)
(Velcro fastening)
- Detach side panels from front section (3+4):
Release each of the 2 hexagonal socket. head screws
inside the pillar covering (1), push the covers forward,
then tilting sidewards pull off from the leg rest pipes as
shown in Fig. 3
4.
Prepare the cover sections (1+2) for connection of the
installation shaft (Fig. 2):
- Cut out a 120 mm dia. section as shown in the
illustration
- Make sure that the mounting side corresponds to that
shown in the installation diagram.
5.
Align the substructure (6) according to the installation
template and secure to the floor. Use 6 rubber washers
(6.1) between framework and floor.
6 anchor bolts M 10 x 125 (extending 30 mm above the
finished floor) or metal plugs with metric thread for
hexagonal screws M 10 x 60.
10. Fit 2 angle brackets each to the column cover and wall for
the installation shaft (fig. 2).
Caution: - Fit angle bracket inside the installation shaft!
If necessary shorten the installation shaft
Caution: - The ends of the shaft must be fitted with edge
protection!
Fit lower shaft component. Fit upper component onto
the top
11. Only for in-line installation:
- Attach 2 angled mounting brackets for the installation
duct at each column housing (Fig. 2)
Caution:
- Attach brackets inside the installation duct!
- Duct ends must be protected with edge covers!
Mount lower part of duct. Place upper part of duct on top