3.11.1. Switching on installer menu
2
RH%
Hold down button (1) at the right for approx. 10 seconds
until the displays (2) and (3) start flashing and the
ventilator level 3 (4) appears.
The installer menu remains active for one hour or until you
press the button (1) again for 10 seconds.
3.11.2. Readout software versions
RH%
2
1. Switching on installer menu, see page 16.
2. Press button (1) at the left.
The display (2) shows the software version of the room
ventilation unit.
3. Press the bottom of button (1).
The display (2) shows the software version of the remote
control.
4. Press the bottom of button (1).
The display (2) shows the software version of an acces-
sory.
If you have more than one accessory installed, press the
bottom of button (1) again.
5. Hold down button (1) at the right for approx. 10 seconds.
The installer menu is closed.
16
OI remote control for Pluggit Avent
3
1
Die Wohnraumlüftung
4
M+P-26A-0978
1
Die Wohnraumlüftung
M+P-26A-0979
3.11.3. Readout rotational speeds of supply and exhaust
ventilators
RH%
4
2 3
1. Switching on installer menu, see page 16.
2. Press button (1) at the right until the display (2) and the
supply air duct (3) start flashing.
The rotational speed of the supply air ventilator appears
on display (4).
3. Press the bottom of button (1) until the display (2) and
the exhaust air duct (5) start flashing.
The rotational speed of the exhaust air ventilator ap-
pears on display (4).
4. Hold down button (1) at the right for approx. 10 seconds.
The installer menu is closed.
3.11.4. Reading out/setting set points of the preheating
(optional)
RH%
1. Switching in installer menu, see page 16.
2. Press button (1) at the right until the display (2) and the
temperature (3) start flashing.
3. Press centre of button (1).
4. Press top or bottom of button (1) until the desired set
point is reached.
5. Press centre of button (1).
The setting is saved.
6. Hold down button (1) at the right for approx. 10 seconds.
The installer menu is closed.
5
1
Die Wohnraumlüftung
M+P-26A-0981
3
1
Die Wohnraumlüftung
2
M+P-26A-0982