Surrounding aperture
The insert is constructed in a way that makes it possible to make the brickwork shut almost tight around the
insert the first 10 cm in the depth from the front. This means that the hole in the front brickwork must be 54-
55 cm high and 58.5-59 cm wide. After the first 10 cm in the depth there must be 2.5 cm air space around
the insert which gives a minimum total width of 63.5 cm. and a total depth of minimum 49 cm in the hole. It is
very important to ensure the 2.5 cm air space around the insert and that the installation is correct, otherwise
the fireplace insert will not cool down sufficiently. A correct cooling is crucial for the energy efficiency as well
as for the function of the Aduro-tronic.
The front of the insert with the frame covers an area of 57.4 cm in height and 63.5 cm in width.
When making the whole in the brickwork then please also remember that you might need some extra space
when the pipe has to be mounted.
2.1 Position of the stove / distance requirements
The new fireplace insert must be installed in a suitable and physically possible position. You need to be sure
that the position complies with local regulations. Distance requirements will only apply if the fireplace insert is
to be placed close to flammable materials. See below:
Distance to flammable material
Behind the fireplace
insert
25 cm
Flue deflector (steel)
To the sides of the
fireplace insert
30 cm
Flue outlet
cover
Vermiculite tiles
To furniture
110 cm
Minimum height above
floor level
26 cm
36