The LEDs on the charging cradle provide the following information:
Signal
Meaning
The battery is charging.
The battery is fully charged.
Error during the charging process.
To ensure that a fully charged battery is available at all times, Dräger
recommends always placing the rechargeable battery into the
charging cradle when it is not in use. Loss of capacity due to a memory
effect will not occur. If the rechargeable battery/thermal imaging
camera is left in the charger, the charger will recharge the battery from
time to time to ensure that it is always fully charged when needed. This
will not damage the battery.
When the battery is fully charged, the battery icon shows 4 green bars.
The battery icon changes in relation to the charging status:
3 green bars: battery power amounts to 75 %
2 orange bars: battery power amounts to 50 %
1 red bar: battery power amounts to 25 %
Replace the battery as soon as possible.
1 red flashing bar: There are only 5 minutes left until the thermal
imaging camera will switch off.
Replace the battery immediately.
Dräger UCF 6000, UCF 7000, UCF 8000, UCF 9000
3.2.4

Changing the battery

1. Loosen the screws under the
handle with the supplied Allen
key.
2. To push the old battery from the
handle, slide the Allen key
through the opening in the
handle.
3. Remove the old battery.
4. Make sure the seal on the new
battery is clean. If necessary,
wipe the contact surface with a
lint-free cloth.
5. Insert the new battery into the
handle of the thermal imaging
camera.
6. Tighten the screws.