Water Supply Requirements

If local codes permit, the chiller feed line should be connected
to the cold water supply line with a ''T'' water line connector
(sold separately). If you are using a ltration unit, the chiller
should be connected after the lters.
IM PORTANT: If local codes do not permit the use of the ''T''
water line connector, special feed valves can be obtained from
your local plumbing supply retailer.
Caution: The feed valve must allow water to ow back into the
building's water supply piping to avoid extreme pressure building
up as the water is chilled. Failure to relieve this pressure will
damage the chiller system and result in a water leak.
The water pressure to the chiller should be between 30 psi (MIN )
and 100 psi (MAX).

Installation Instructions

How to insert/remove tubing in easy connect tting
Insert the tubing squarely. See gure A.
Make sure to insert tubing completely. See gure B.
Push in collet and pull out tubing. See gure C.
Tube
Collet
Body
Figure A

Install the Chiller

N OTE: Tubing must be cut to t. All tubes must be cut squarely
with no burrs. All tubing connections must be fully seated.
Tubing must be routed to avoid sharp bends and have enough
slack to avoid straining connections. A P-clip and mounting
screw are included to hold the tubing in place as needed. Pull
gently on each connection to make sure they are secure.
IM PORTANT: After chiller is unpacked, place chiller upright for
24 hours before plugging it in.
1 . Determine where you will install your chiller.
See ''Location Requirements'' section.
2 . For best performance, allow a 2" (5 cm) space around
the side and the top. Do not put any objects on top of
the chiller that could obstruct the fan.
3 . Shut o water supply valves.
4 . Install faucet (sold separately).
See faucet's Installation instructions.
5 . Cut a piece of white tubing to connect the chiller (water in)
to the water supply tting (part 7) or lter outlet (if applicable) .
(see gure 1)
6. Connect elbow ttings to chiller inlet and outlet tubes.
7. Connect water supply tube to tting on chiller "water in."
8. Connect faucet tubing to chiller "water out."
part 10
9. Slowly turn on the water supply valve. Open faucet until
water ows for about one minute. Check all connections
for leaks.
10. Plug in the chiller.
11. Prior to drinking water from chiller ush water through the
part 7
chiller for about 5 minutes.
Figure 1
Figure B
Figure C
part 10
N OTE: If you are installing the chiller and a ltration system
without a bladder tank, follow steps 6a to 12. Following these
steps will avoid the possibility of excessive pressure building as
the chiller cycles on and o . If you are installing a bladder tank
with your ltration system, the bladder tank must be connected
directly to the chiller without any regulators or back ow
preventers between them. If you are NOT installing the chiller
with a ltration system or if your lter system includes a bladder
tank, follow steps 6b. and 10 to 12.
6a. Connect "T" (part 10) to "water out" chiller tube. Connect blue
tubing between "T" and faucet, sold separately. (see gure 2)
Check valve
White tubing
(part 11 )
to check valve
6b. If you are NOT installing a ltration system, connect blue
tubing between the"water out" chiller tube and faucet, sold
seperately. Do NOT use "T" quick
check valve (part 11).
7. Cut 6 inches of white tubing. Connect one end to "T"
(part 10) that is connected to "water out" chiller tube and
other end to check valve inlet ( see gure 2).
8 . Cut white tubing to connect the water supply tting
(part 7) and the inlet of the ltration system. Connect the
straight-thru ports of the second "T" (part 10) to the loose
ends of the white tubing just cut. (see gure 3)
9 . Connect white tubing included with chiller between the third
port of the second "T" (part 10) and check valve outlet (see
gure 3).
White tubing
to ltration
"T" Quick
connect tting
(part 10 )
10 . Slowly turn on the water supply valve. Open faucet until
water ows for about one minute. Check all connections
for leaks.
11 . Plug in the chiller.
12 . Prior to drinking water from chiller, ush water
through the chiller for about 5 minutes.
Blue tubing to faucet
"T" Quick connect tting
(part 10 )
Connection to Chiller
water "out"
Figure 2
F i g u r e 1
ttings (part 10) or
Check valve
(part 11 )
Connection to part 7
Figure 3