WATER CONNECTION
WARNING: The system must be
connected to the potable water supply
network.
WARNING: It is recommended to
install a valve at the water input of the
cooler, in order to isolate the system
from the water supply whenever it is
necessary.
When the customer is not able to
Z
X
service, it is recommended to install
a device that automatically stops
water flow and isolates the product
from the water circuit (our sales
department is available for further
technical specifications).
No tools are required to connect the
system to the drinking water tube.
Connection is carried out easily and
within seconds, simply by inserting the
tube directly into the rapid connection
located on the back/side of the product.
This product is supplied with 3/8" rapid
connections if the connections are white
(or beige).
Before connecting the water tube
Z
X
be sure that there are no traces
of impurities in the inlet rapid
connection. A dust cap may be
present, if so, it is necessary
to remove it before water tube
connection.
CAUTION: The incoming water
pressure must be between 2.5 bar and
5.0 bar. The flow rate should not be less
than 3 liters/minute.
WARNING: Check that the
pressure remains constant even while
water is being dispensed or at least
that variations do not exceed 1.0 bar. If
this is not the case, reduce the length
of the connection tube, or increase the
internal cross-section.
To ensure proper installation, it is
recommended to use only certified
food-grade tubes and fittings.
CAUTION: If incoming water
pressure is unknown, a „water pressure
reducer" must be installed and set to
2.5-3.0 bar. Again, check that the
pressure is maintained within this range
even while water is dispensed, or that
variations do not exceed 1.0 bar.
– 7 –
EN