Always select a temperature that is reasonable!
Example
Always select a temperature of water in the margins of temperature of the
cold and hot water. If there is a cold water temperature of 5 degrees, and you
requested the mixer water at 3 degrees, it will open the passage of the cold
water; but the temperature will not arrive at 3 degrees, because the minimum
is 5 degrees.
3.1. For correct mixer operation
1.
The diameter of the pipes must always be equal or superior to 18 mm to
guarantee a correct volume. The pressure has to be equal or superior to
1 bar as well, 3 bars being the ideal in both entrances.
2.
The inlet pressure of cold and hot water must be similar, if there is a
difference superior to 1.5 bars, the regulation of the temperature can be
difficult
3.
If the temperature of the mixed water is very different from the selected
one, you can readjust the mixer. Remove the cover and screw. Extract
the graduated control and insert the real temperature to which the mixed
water comes out.
3.2. Automatic tuning pulses
Only in case of a measurement error
1.
Before switching ON the equipment hold the "off" key pressed.
2.
Move Power SWITCH to position I.
3.
The message "P-L" is displayed.
4.
Prepare a container of 10L.
6