Painting the stove with the senotherm-spray can cover spots or small scratches. Larger damages
need to be ground with fine steel wool, vacuumed and then sprayed. Shake the can vigorously
and then spray from a distance of about 15-20 cm. It is important the stove is not in use and
completely cold before you use the spray due to the fire hazard. In order to keep the stove's
varnished surfaces looking nice for many years to come please refrain from touching the surface
when the stove is hot. Ensure sufficient ventilation when spraying.
7.7. Glass
The glass does normally not need maintenance apart form cleaning. This is done by using Ter-
maTech's glass cleaner. Termatech glass cleaner must only be used when the stove is cold. Item
number 43-102.
7.8 Disposal of the glass
If the glass is broken it cannot be disposed with normal glass waste as it is ceramic glass (to be
disposed as ceramic)
8.0. Adjusting the stove
8.1. Adjusting the doors auto lock
On the door/hinge on your TT70 is a spring This makes the door automatically close when you let
go of the handle. The closing devise is not a demand, however, we recommend to keep this func-
tion. If you wish it can be removed by taking off the split with the lentil head (on lowest hinge)
whereby the tension is removed from the spring. This can easily be done by using a flat screw-
driver and pliers. See section 13.2.
8.2. Adjustable feet
There is mounted 5 adjustable feet under the stove. There is two ways for adjusting the 5 feet.
The adjusting can be done through the air hole in the back of the stove with a 5mm unbrako
wrench, or from outside with a 17mm wrench. See section 13.3.
8.3. Adjusting the top plate
If you wish to adjust the height of the top plate or if it tilts a bit, it can be lifted and the nuts un-
der the top plate screw up and down to achieve the desired result. Read section 13.5.
9.0. Warranty
9.1. 5 Year warranty
If defects/faults are ascertained, use of the wood burner must be stopped immediately and the
dealer contacted.
Provided normal operation of the wood burner, TermaTech offers a 5 year warranty on material
and manufacturing faults on the load-bearing frame, exclusive of the combustion chamber.
9.2. Combustion chamber The following is not covered by the warranty
Combustion chamber, cast iron parts (bottom, door, grate) insulation material (vermiculite plates)
smoke deflector plates, glass, gaskets, the closing mechanism/handle and the handle.
9.3. Exterior parts The following is not covered by the warranty
Varnished plates/surfaces, stone facings, glazed tiles, concrete and glass, as well as the closing
mechanism/handle and magnets.
9.4. The warranty does not cover faults which are due to:
•
If the user/mounting guide is not being followed
•
The mounting has been carried out incorrectly
•
Overheating / deterioration of materials, caused by the use of incorrect type of fuel, petro-
leum coke or too much fuel
•
that the product has been connected to a chimney with poor drawing qualities. For example
chimneys that are too short or are leaking.
•
The product being positioned or has been positioned/kept in unheated or damp surroundings.
•
The product being in bad repair or not maintained according to the instructions.
•
Normal wear and tear of wearing parts/expendable parts as well as the varnish.
•
Similar circumstances which are not due to material or manufacturing faults.
The lesser defects below, which cannot support any claim, can occur in the product:
•
Naturally occurring variations in the colour nuances and marbling on the soapstone, sandsto-
ne and other stone cladding.
•
Sounds which occur during burning are normal. This occurs when the metal expands and
retracts.
35