2) Fixing the comfort temperature :
The comfort temperature that you would like while the room is occupied.
a) Set the cursor
b) Set the control knob
c) Wait a few hours until the temperature stabilizes.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position.
If the setting is not satisfactory, adjust it and start again from point c.
3) Fixing the Eco temperature :
This involves a reduction in degrees compared to the Comfort temperature. We recommend that you use this mode
for periods of absence of more than 2 hours or overnight.
Warning: This reduction applies to the Comfort temperature so it is important to set the Comfort temperature first,
before setting the Eco reduction.
a) Set cursor
to , indicator light, V3 light up.
2) Set the wheel
to –3.5°, the heating indicator light V1 comes on if the ambient temperature is less than the desired
Eco temperature.
c) Wait a few hours until the temperature stabilizes.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position.
If the setting is not satisfactory, adjust it and start again from point c.
NB: The measurement is set to –3.5°C in our laboratories. It is possible that the setting for the reduction is not precisely
–3.5°C, depending on your installation's particular characteristics. In this case, adapt the setting to obtain the desired
reduction.
4) Frost-Free mode :
This mode is used to keep the temperature at approximately 7°C in the room when you are absent from the house for
a prolonged period (i.e. more than 24 hours).
a) Set the cursor
5) The heating indicator : V1
This light indicates periods during which the element is heating. It flashes when the temperature is stable, and it goes
off if the temperature is too high.
6) Stop heating :
Move the cursor
7) Locking the controls : 6 6 6 6 6
It is possible to lock or limit the range of use of thumb-wheels
selector switch cursor
(by children, etc).
a) Detach the device from its wall bracket.
b) On the back of the thermostat box, detach pins P from their supports.
c) Choose position B to lock the thumb-wheels or position L to limit the range of
use of the thumb-wheels.
Choose one of the positions M to lock the person in the desired mode.

8) Programming mode :

This device has a thermostat capable of receiving orders through its pilot wire. It
recognizes the following commands:
- CONFORT (comfort)
- CONFORT –1 (comfort –1) : Temperature set using the thumb-wheel
- CONFORT -2 (comfort –2) : Temperature set using the thumb-wheel
- ECO
- HORS GEL (frost-free)
- STOP HEATING
To activate the programming mode set cursor
In this way, by connecting the pilot wire to a timer, you can program your Comfort and Economy temperature periods.
It is possible to connect several devices to one timer and, in this way, make energy savings.
NB: When there is no command given over the pilot wire, the device heats in the Comfort mode. HG and load-shedding
commands override the Economy and Comfort modes. On changing from the Comfort mode to the Economy mode,
the changeover time is approximately 12 seconds.
,
to
the heating light V2 comes on.
to 5, the heating light V1 comes on, if the room temperature is below the required temperature.
to
.
to
.
to prevent the inadvertent manipulation of the device
: Temperature set using the thumb-wheel
: Temperature set using the thumb-wheel
: Room temperature maintained at approximately 7°C
: Immediate stoppage of the heater (used for load-schedding).
and
and lock