Velleman DVM630 Mode D'emploi page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

power supply
dimensions
weight
accessories
9.1 Accuracy
Accuracy is specified for a period of one year after calibration and at an
ambient temperature from 64 °F to 82 °F, with relative humidity < 75 %.
Range
200 mV
2 V
20 V
200 V
600 V
Overload protection: 220 VAC for 200 mV range; 600 VDC or VAC for other
ranges.
Range
200 V
600 V
Overload protection: 600 VDC or VAC for all ranges.
Frequency response: 45 Hz – 450 Hz.
Range
2 mA
20 mA
200 mA
10 A
Overload protection:
fuse 1: 200mA/600V (resettable)
fuse 2: 10A/600V (fast).
Measurement voltage drop: 200 mV.
When measuring currents up to 10 A, max. 10 seconds continuous
measurement followed by a 15 minutes break between 2 measurements.
V. 01 – 22/04/2013
DVM630
2 x AAA 1.5 V R03P SUM4 battery (incl.)
6.4" x 2.9" x 1.5"
8.96 oz (including battery)
user manual, test leads, holster, batteries, adapter
for transistor measurements, cable test unit
DC voltage
Resolution
100 µV
1 mV
10 mV
100 mV
1 V
AC voltage
Resolution
100 mV
1 V
DC current
Resolution
1 µA
10 µA
100 µA
10 mA
17
Accuracy
± (0.5 % of reading + 2 digits)
± (0.8 % of reading + 2 digits)
± (1.0 % of reading + 2 digits)
Accuracy
± (1.2 % of reading + 10 digits)
± (1.2 % of reading + 10 digits)
Accuracy
± (1.0 % of reading + 2 digits)
± (1.2 % of reading + 2 digits)
± (2.0 % of reading + 2 digits)
©Velleman Inc.