Unit Specs; Utility Requirements; Quick Disconnect Installation - Kasco 2400EVX Guide D'utilisation

50hz
Masquer les pouces Voir aussi pour 2400EVX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

circuit interrupter) protected circuit.
Do not modify any mounting hardware or guarding
provided with this equipment. All guarding
purchased with a unit must be installed.
This equipment is intended to operate without
interaction from personnel. Never to be
manipulated, moved, maintained, or adjusted while
in operation. Damage or injury could result.
The general public must be made aware of the
installation and warned of the installation to
prevent misuse or interference with the equipment.
This equipment is intended to be used in water
only. The equipment should only be operated
out of water if required to troubleshoot operation
and during initial startup of the equipment. The
instructions provide detailed warnings and
instructions for such activities and should only be
performed by a trained person.

Unit Specs

Model
Voltage
range
2400EVX
208-240
3400EVX
208-240
4400EVX
208-240
2400EJ
208-240
3400EJ
208-240
4400EJ
208-240

Utility requirements:

The Electrical circuit must be provided to supply suf-
ficient voltage and amperage to the unit. These ratings
are listed in the above table (unit specs). This circuit
must also include a disconnect means and short circuit
protection.

Quick Disconnect Installation

Important – Read Carefully Before Installation
Before using the connector, it is important that these
instructions are carefully read and understood to
ensure the connector system is completely water tight
Operating
lock rotor
amps
amps
2.2@220V
6@220V
3.6@220V
9@220V
5.9@220V
20@220V
2.8@220V
6@220V
3.4@220V
9@220V
6.5@220V
20@220V
and electrically safe.
IF IN DOUBT CONSULT A QUALIFIED ELECTRI-
CIAN.
The socket (female) insert of the connector must be
the live part of the connector from the supply. The pin
(male) insert of the connector must lead to the load or
electrical device. On 50Hz units, the pin (male) insert
of the connector is installed at the factory. To ensure
efficient sealing, use only smooth circular cable.
Pin Insert (Installed on Stub Cord)
Main Body
Pin Insert
Socket Insert (User Installed)
Socket insert
Main Body
Note:
White gland for 9-11mm O.D.
Yellow gland for 13-15mm O.D.
Assembly/Wiring Instructions
1. Remove the socket insert from the housing
of the connector. There is a slot for a flat blade
screwdriver in the center of the insert.
Note: The inserts have a LEFT HAND
THREAD and should be turned clockwise to remove.
2. Remove the gland nut and gland from the rear of
the housing and slide on to the cable. Make sure the
gland is orientated with the stepped edge facing the
gland nut (see picture).
Gland
Gland Nut
Gland
Gland Nut
Stepped Edge
3

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

3400evx4400evx2400ej3400ej4400ej

Table des Matières