INSTALLATION MANUAL
DGM1D
1-Door Mifare
controller/reader system
®
Mounting instructions
The DGM1D has to be installed in a protected
environment compliant to the level 2 of the NF
EN 61000-4-4. The wires should not be close
to other source of energy (Ex.: power supply, main
power line, etc.).
Checking during the installation
Once the installation is completed, during powering
the controller, the reader LED color is orange during
4 seconds and turns off after, the LED will stay off
until a badge is swiped.
Access Control operating mode:
3 different mode to program a badge:
- Standalone (remove jumper JP2
on the controller),
- Terminal unit (put the jumper JP2 on the controller),
- Software + terminal (put the jumper JP2
of the central unit).
Notes: To change modes, use the jumper JP2
after the power supply of the central unit is off.
When You change modes, all the data from the
previous mode are erased.
A - STANDALONE MODE (WHITE LIST)
How to create or replace a Master Badge
- Put JP1 jumper on the controller,
- Swipe a badge in fgront of the reader,
- Remove jumper JP1.
How to add a badge (max. 200)
- Swipe the Master Badge in front of the reader,
to enter in programming mode (the LED turns
amber for 2 seconds),
- Enrol the badges;
30 seconds after the last badge is programmed,
the controller exit from programming mode
(The LED turns solid orange for 10 seconds
– during this step, do not do swipe any badge).
Delete all the badges (reset
to the factory default values)
- Turn off the power on the controller,
- Put JP2 jumper,
- Turn on the power; The LED of the reader
turns on solid red; the reset is completed when
the LED starts fl ashing in red,
- Turn off again the power on the controller,
- Remove jumper JP2,
- Turn on the power supply; the controller is ready
to be reprogrammed,
Note: the Master Badge is not deleted.
Lock time
- The programming is done with the button
connected to the terminal J5,
- Present the Master Badge on the reader,
- Push the button: a push corresponds to one second
of relay opening time (10 pushes = 10 seconds),
- 30 seconds after the last press on the button the
central unit leaves the programming (the LED of
the control unit is fl ashing a number of times
corresponding to the seconds programmed as relay
opening time: for example 10 seconds = 10 blinking).
B – HANDHELD TERMINAL (BLACK LIST)
In this mode, the controller ref. PCV123D
gives more functionality than
the previous mode:
- Unlimited number of users;
- Possibility to delete badges;
- Possibility to create a black list of badges with
no access to the site (max. 200 badges);
- Possibility to add passes badges
to access multiple sites.
For more information, refer to
the PCV123D manual.
C - SOFTWARE + HANDHELD TERMINAL (BLACK LIST)
The software comes with the PCV123D handheld
terminal. It is intended to bring more functions
such as a user database and manage the backups.
For more information about the software, read
the online user guide.
Recommended power supplies
ARD12 or BS60.
CE Standards
The DGM1D controller is compliant with directive
R&TTE1999/5/CE: electrical safety norm EN
60950(2000), norm CEM EN 50130-4, applied RF
norm EN 300 330-2(2001).
EN
cdvi.com
13