MAINS OPERATION & RESULTING TEMPERATURE
The following tables allow determining power supply and cabling requirements.
The power drawn from the mains network is converted into output power to feed the connected
loudspeaker systems and into heat. The difference between power consumption and dispensed power
is called power dissipation (Pd). The amount of heat resulting from power dissipation might remain
inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is
meant as auxiliary means for calculating temperatures inside of a rack-shelf system/cabinet and the
ventilation efforts necessary.
The column „Pd" lists the leakage power in relation to different operational states. The column „BTU/hr"
lists the dispensed heat amount per hour.
CP1800
idle
Max. Output Power @ 8Ω
Max. Output Power @ 4Ω
1/3 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
Normal Mode (-10dB) @ 4Ω
Rated Output Power (0dB) @ 4Ω
Alert (Alarm) Mode (-3dB) @ 4Ω
Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
CP2200
idle
Max. Output Power @ 8Ω
Max. Output Power @ 4Ω
1/3 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
1/8 Max. Output Power @ 4Ω
Normal Mode (-10dB) @ 4Ω
Rated Output Power (0dB) @ 4Ω
Alert (Alarm) Mode (-3dB) @ 4Ω
Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
1/8 Max. Output Power @ 2Ω
(1) Sine Modulation (1kHz)
(4) 10% Mains Over Voltage
The following factors allow direct proportional calculation of the mains current Imain for different mains
supply voltages: 100V = 2.3; 120V = 1.9; 240V = 0.96.
MAINS OPERATION & RESULTING
U
I
mains
mains
[V]
[A]
230V
0,39
(1)
230V
6,7
(1)
230V
11,0
(1)
230V
6,6
(1)
230V
2,7
(2)
230V
3,3
(2),(4)
230V
3,5
(1)
230V
2,5
(1)
230V
10,2
(1)
230V
7,4
(1)
230V
17,0
(1)
230V
4,0
(2)
230V
4,9
U
I
mains
mains
[V]
[A]
230V
0.5
(1)
230V
8.0
(1)
230V
13.2
(1)
230V
7.5
(1)
230V
3.0
(2)
230V
3.3
(2),(4)
230V
3.6
(1)
230V
2.8
(1)
230V
12.5
(1)
230V
8.8
(1)
230V
20.0
(1)
230V
4.5
(2)
230V
4.5
(2) VDE-Noise
(5) Pd = Leakage Power
P
P
mains
out
[W]
[W]
46
-
1110
2 x 350
1980
2 x 600
1090
2 x 200
410
2 x 75
480
2 x 75
500
2 x 84
370
2 x 60
1810
2 x 500
1250
2 x 250
3290
2 x 900
660
2 x 113
790
2 x 113
P
P
mains
out
[W]
[W]
65
-
1440
2 x 500
2520
2 x 800
1360
2 x 266
520
2 x 100
570
2 x 100
660
2 x 120
470
2 x 80
2360
2 x 700
1610
2 x 350
4000
2 x 1100
815
2 x 138
815
2 x 138
(3) 1BTU = 1055.06J = 1055.06Ws
9
Pd
(5)
BTU/hr
(1)
[W]
46
155
410
1400
780
2660
690
2355
260
885
330
1125
332
1130
250
855
810
2765
750
2560
1490
5085
434
1480
564
1925
Pd
(5)
BTU/hr
(3)
[W]
65
220
440
1500
920
3140
828
2825
320
1090
370
1260
420
1435
310
1060
960
3275
910
3105
1800
6140
540
1840
540
1840

Publicité