Brooks Instrument Ar-Mite MT3750 Manuel D'installation Et D'utilisation page 7

Masquer les pouces Voir aussi pour Ar-Mite MT3750:
Table des Matières

Publicité

Tableau 1-3 Valeurs nominales de pression du MT3750C en PSIG (BarG)
Mètre
Type
Compteur standard
Compteur haute pression
Tableau 1-4 Température du fluide MT3750C à température ambiante
Temp. Amb.
Température
°F
°C
-58
-50
-20
-29
104
40
110
43
120
49
130
54
140
60
150
65
Remarques :
1. L a température ambiante est limitée à 150 °F (65 °C) maximum. Contactez l'usine pour une température ambiante> 150 °F
(65 °C)
Tableau 1-5 Cotes de température MT3750C pour les matériaux élastomères
Température minimale
Élastomère
Matériaux
°F
Kalrez 4079
-58
Viton A
5
Teflon PTFE
-58
Buna
-22
Éthylène Propylène
-58
Tableau 1-6 Agréments — MT3750C
(Tableaux de référence 1-7, 1-8 et 1-9 pour les certifications avec émetteur, alarme de contacteur Reed et alarme inductive)
Meter Options
Approvals
Mark
EU Declaration of
Conformity
CRN
IP66/67 & NEMA 4X
IP66/67
IP65
Type 4X
Explosion safety
ATEX
"Constructional
safety (c)"
Brooks
Ar-Mite™ MT3750C
®
Note de pression
-58 °F à 400 °F/-50 °C à 204 °C
1500 (100)
4000 (276)
Indicateur
°F
°C
-58 to 400
-50 to 204
400
204
400
204
390
199
380
193
370
187
360
182
350
176
Température maximale
°C
°F
-50
400
-15
400
-50
400
-30
250
-50
250
Standards/Directives/Marking
EMC Directive (2014/30/EU)
RoHS Directive (2011/65/EU)
Pressure Equipment Directive (2014/68/EU)
ASME B31.1 & ASME B31.3
IEC 60529 & NEMA 250-2014
IEC 60529
IEC 60529
CSA
II2G Ex h IIC T6...T3 Gb
II2D Ex h IIIC T200°C Db
Special conditions for safe use:
Enclosure contains glass & painted aluminum parts. If it is mounted in an area w here the use
of category 2G or 2D apparatus is required, it must be installed such that ignition source due
to propagating brush discharge sparks are excluded.
The actual maximum surface temperature of the equipment depends not on the equipment
itself, but on operating conditions of the process fluid/gas flow ing through the equipment.
The equipment by itself does not generate heat. Due to this reason the temperature class is
marked as a range. The maximum permitted ambient and process temperature limits can be
found in the operating instructions.
At start up especially for gas applications, ensure that the pressure is gradually increased
through the piping system. A sudden pressure spike situation may result in a fast movement
of the float w ithin the VA flow meter & the float may hit hard against the float stop.
Supply grounding connection by the process connections or earthing terminal.
max. T empérature du fluide par option max.
Alarme
°F
°C
S.o
S.o
-20 to 250
-29 to 120
250
120
250
120
250
120
250
120
240
115
235
112
°C
204
204
204
120
120
Declaration/Certifica
te
Declaration
Declaration
Declaration - SEP
CRN
Declaration
DEKRA Certificate/ UL
DEKRA Certificate
CSA / UL Certificate
MBID 022
Section 1 Introduction
Émetteur
°F
°C
S.o
S.o
-20 to 180
-29 to 82
180
82
175
79
170
76
165
74
155
68
150
65
3

Publicité

Table des Matières
loading

Table des Matières