Indoor monitor configuration as master
The monitor contained in the KIT is configured as master.
Monitors purchased as an individual reference (MON 43 or
MON 70) outside the kit are configured as slaves.
After making the connections and connecting the power su-
pply to the network, press the
4 tones will be heard. Then press the call button on the out-
door panel. The monitor will hear a tone and an image will
be displayed. Press the
4 tones will be heard. The monitor is now set to master.
Indoor monitor configuration as slave
After making the connections and connecting the power supply
to the network, press the
be heard on the monitor. Press the call button on the outer pla-
te. The monitor will hear a tone but no image will be displayed.
Press
for 3 seconds again and 4 tones will be heard. From
this moment, the monitor is configured as a slave.
Verification of coded equipment:
Outdoor panel.
To identify whether the outdoor plate is configured as master or sla-
ve, press the monitoring button
outer board will be displayed.
To identify whether the outdoor panel is configured as a slave, press
the monitoring button
until it shows the image of the street panel
configured as slave.
Indoor monitor.
When the whole system is configured correctly there is no distinction
between master or slave monitor. However, if only one monitor is left
connected, we can find out its configuration in the following way:
Press the button bell button. If picture and audio are displayed, this
monitor is set to master. If, on the other hand, only audio is heard, the
monitor is configured as a slave.

5. SYSTEM ADJUSTMENTS

Once done the first installation make the following adjustments:

5.1. Outdoor unit

Adjust again the camera angle of the outdoor unit in order to
take best frame possible of the image at the street.
Adjust the volume level of the outdoor unit with the potentiometer at
the front side.
96
button for 3 seconds and
button again for 3 seconds and
button for 3 seconds. 4 tones will
once. The image of the master
5.2. Indoor monitor
Adjust the brightness and colour of the monitor
Adjust the level of contrast of monitor (Model MON 70)
Adjust the volume level of the speaker
Adjust the volume level of the call
5.3. Coding the RFID Keys
(ONLY FOR KVP 2700 / PE 2)
The KVP 2700 is provided with a total of 7 RFID keys that can be
linked and unlinked at any time. Even additional user keys can be
linked in case of loss.
5 blue keys for normal opening use (user keys)
1 yellow key for increasing the number of user keys (linking)
1 red key for decreasing the number of user keys (unlinking)
Keys are linked from origin. Anyhow here it is explained the linking
and unlinking process in case of acquiring new ones. This process
requires removing the outdoor panel and opening it by unscrewing
the four screws in order to access into the inner electronics:
LED
Normal mode
Configuration mode
View of the rear internal outdoor
panel once opened
Yellow and red keys coding:
1.
Being the outdoor unit disconnected, set the jumper of the
reading card in the configuration poistion (This position means
shorting the second and third terminal.
2.
Connect the outdoor unit to the power supply.
3.
Pass the yellow key through the front reader. A short sound will
be heard and the led will remain in red colour. The yellow key is
set.
4.
Pass the red key through the front reader. A short sound will be
heard and the led will remain off. The red key is set.
5.
Disconnect again the outdoor unit from the power supply
and set the jumper back to the normal mode (short the first
and second pin).