Cable Testing
Plug one end of the cable to be tested into the Tester Control Unit and the other end into the
Tester Display Unit. Due to their smaller size, when testing 6P6C, 6P4C cables ensure they are plugged
firmly into each of the Testing Units.
Quick Test - Press the Test button on the Control Unit to start the test.
Extended Test - Press & hold the Test button for 3 seconds and then release. The Tester will repeat the
single test 12 times.
To stop the Extended Test at any time simply press the Test button again.
The Test Units will power off automatically when the testing process has completed.
Low Battery Indicator - LED #1 will flash when the Test button is pressed.
Note - The LEDs may not light up in a sequential order depending on the mapping of the cable tested.
Detaching the Cable Testers
Squeeze the handles of the Tool together and release to open.
Detach the Test Units by pressing the catches on the top & bottom of their housing and slide up from the
tools handles.
Reverse the steps above to reattach the Test Units.
Cable Tester Results
The 4-in-1 Crimp & Cable Tester Tool displays cable map results for Pass, Shorts and Mis-wire for
pin-to-pin test in the following way.
Pass:
Short:
Mis-wire:
Low Battery: When the batteries are low PIN 1's LED will flash when the Test button is pressed.
Pass
The LEDs will light from PIN 1 to PIN G in order 12345678G > 12345678G
The
LEDs
will
eg. if PIN1, PIN2, PIN7 & PIN8 corresponding pins are shorted the display unit
would show 12345768G > 12345678G
If the pins are mis-wired the LEDs will light up disorderly in unmatched pairs
12345678G > 68745321
highlight
shorted
Short
2
User Manual
pins
after
the
Mis-wire
map
test.