dirna Bergstrom bycool green line DINAMIC 1.1 SCANIA Instructions De Montage page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DINAMIC 1.1
Position the bushing and nut covers.
6
6
Use bushing to pass the wastewater pipe
7
through the Ø19 borehole to the inside of the
cabin.
On the studs, screw on (4) M6 nuts with (4)
8
Ø6 flat washers, which should be level with
the cover.
SEE ATTACHED DIAGRAM
VERY IMPORTANT
!
In the case of slanting upholstery, the
evaporator unit must be vertical or sloping
from the lower section to the outside in
order to prevent the condensation water
from dripping onto the upholstery.
Upholstery
Evaporator
bracket
Wastewater
tray
Wastewater
pipe
Air conditioning for vehicles
6
7
Lorry sheet
OUTSIDE
M6 self-blocking
nut
Protector cap
M6 Stud
Wide ring flat
washer
Rubber washer
21
Upholstery
INSIDE
Evaporator
M6 Nut
base
(leave at
M6 Nut
upholstery height)
M6 Nut
Wide ring
Wide ring
flat washer
flat washer
EN
8

Publicité

Table des Matières
loading

Table des Matières