INTENDED USE

NOTE
Intended use in the operating media refers to the level gauge type FSA-E.
Operating media
Fuel oil
Fuel oil Bio
Diesel fuel
FAME
Vegetable oil
Waste oil
Other water-hazardous, non-flammable liquids
Rainwater
Urea solution
NOTE
You will find a list of operating media with descriptions,
the relevant standards and the country in which they are used at
www.gok-online.de/en/downloads/technical dokumentation/
list of operating mediums.
Other media on request!
Place of operation
Not suitable for outdoor use.

FUNCTION DESCRIPTION

The content of the tank is determined by measuring the level on the basis of the float
principle. With an electronic interface, the measurement from the FSA-E is sent via a
connection cable to the SmartBox
output value and shown on the display.
Installation example - standard installation of SmartBox
®
MINI digital display unit, where it is converted into the set
The FSA-E with electronic interface is set to
the maximum permitted level and is installed
in an existing G 1 1/2 tank connection
opening.
The FSA-E with electronic interface is
connected to the digital display unit with a
10 m cable or a suitable extension cable up
to a distance of 50 metres (see cable
extension option).
16/72
SmartBox
®
MINI
Artikel-Nr. 308 051
®
MINI