2.2 Panic function E

Approved for emergency exits acc. EN 179 and panic doors acc. EN 1125.
Fittings:
In escape route direction:
Outside:
Function inside:
Door can be opened in escape route direction at any time.
Function outside:
Fixed knob or push/pull handle; door can only be opened by using an
authorised key.

2.3 Locks acc. EN 12209 (no panic function)

Approved for fire doors acc. DIN 4102 in combination with fittings for
fire rated doors acc. EN 1634.
Fittings
Function inside
Door can be opend at any time as long as the deadbolt is not locked.
Function outside
Fixed knob or push/touch bar. Door can be opened by authorised key, latch
and deadbolt can will be retracted
Knob/lever
Approved panic device or handle
Fixed knob or pull/push bar
Knob/lever or lever/lever