Heating/cooling topic page
DHW topic page
Heating/cooling operation
1
Zone selection
If multiple zones (heating circuits) are
available, you must firstly select the
zone you wish to configure.
2
The operating mode for each zone
can be set:
Protective mode
Heating switched off
Protective functions active
Automatic
Heating operation acc. to timer pro-
gram
Temperature set-point acc. to heating
program
Protective functions active
Sommer/Winter Umstellautomatik
aktiv
ECO functions active
REDUCED
Heating operation without timer pro-
gram to comfort set-point
Protective functions active
Sommer/Winter Umstellautomatik
aktiv
ECO functions active
COMFORT
Heating operation without timer pro-
gram to comfort set-point
Protective functions active
Domestic hot water operation
In the same way as the zones, you can
also configure settings for the domestic
hot water.
1
Operating mode
On
Domestic hot water preparation is car-
ried out according to the nominal set
point.
Off
Domestic hot water preparation is swit-
ched off.
Eco
Domestic hot water preparation is car-
ried out at a reduced set point.
3
Temporarily
The "warmer" or "cooler" temperature
function allows you to adjust the tempe-
rature for short periods in certain situa-
tions. This adjustment is active for a
limited time, until the next switching
time in the timer program.
(Only possible in automatic operation)
4
Comfort set point
You may set the desired comfort set
point.
5
Time program
Each day has a time program with up to
three available switching periods,
during which the temperature set point
is automatically adjusted.
6
To make adjustments, first select
the day.
7
You can then change the current
time phase or add a new one.
8
You also have the option to copy
the set time program to another day of
the week.
2
If the domestic hot water storage
tank has emptied due to high water
demand, you can reload it to the nomi-
nal set point using the temporary
"recharge" once.
3
The domestic hot water nominal set
point is adjustable according to indivi-
dual needs.
4
The domestic hot water time pro-
gram can be configured as described
under heating/cooling.
Temperature
Zone 1
Operating Mode
Automatic
Temporary
Warmer
Comfort setpoint
22°C
Time program
Heating
Zone 1
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday
Zone 1
Set time program
06:00 to 19:00
00
06
12
18
Copy
Domestic hot water
Operating mode
On
Temporary
Recharging
Nominal Setpoint
50°C
Time program
1
2
3
4
5
14:42
6
zurück
14:42
7
24
Back
8
1
2
3
4
47