Electric vehicle charging unit JOINON WALLBOX I-CON DLM
12.
13.
62
CLEAN CONTACT CONNECTION
The charging station has a clean contact that can be used by external devices to check the charging station,
intervening in the current charging process.
The operating logic is such that if the station is charging and the machine is absorbing energy, receiving this input
causes the station to suspend charging. Charging can only be restarted after receiving a new command. The
restart of the charging process depends on the availability of sufficient power if the station is configured with the
DLM operating mode
To make the correct connection and ensure full functionality, the following must be guaranteed:
Open-circuit voltage: approx. 6V
Short circuit current: 10mA
Cable section: 1mm2
Impulse duration: 500ms
Max. distance: 50mt
CHARGE POWER REDUCTION BASED ON THE INTERNAL TEMPERATURE
The charging station has an internal temperature sensor. Based on the internal temperatures detected, which are
influenced by the environmental conditions and the state of the charging station (stand-by, charging or error),
the charging power can be decreased in order to protect the integrity and operation of the internal components.
For example, charging at 22kW, if the internal temperature exceeds the set threshold, is decreased to 11kW until
the internal temperatures detected do not return below the set limits.
USER
COLLEGAMENTO
CONNECTION
UTENTE