Warnings
WATER CONNECTIONS
• M andatory installation of a safety device in a frost free location
( or any other new device which limits the tank pressure) to 0.7 or 0.9
MPa (7 or 9 bar) according to the nominal pressure, with a size of 3/4''
on the input of the water heater, respecting the local regulations (see
table p.B).
• Hydraulic accessories should not be located between the safety valve
and the cold water inlet. A pressure reducer (not supplied) is required
when the water supply pressure exceeds 0,5 MPa (5 bar) and will
be fitted on the main supply.
• Connect the safety device to an unpressurised outlet pipe in a frost
free location, with a continuous slope to evacuate water during
heating up or draining the water heater.
• Operate regularly the discharge of safety device to prevent scaling
and check that it is not blocked.
• To drain the device : switch off the power and the supply of cold
water, open the hot water faucets and manipulate the safety valve,
• The pipes used must support 1 MPa (10 bar) and 100°C.
ELECTRICAL CONNECTIONS
• Switch off the power before removing the cover, to avoid any risk
of injury or electric shock.
• The installation must be equipped, upstream of the appliance, with
a bipolar cut-out device (fuse, breaker switch) respecting local
regulations (30 mA earth-leakage breaker).
• If the supply cord is damaged, it must be replaced by a special cord
or assembly available from the manufacturer or the after sales
service.
• Always connect the earth conductor of the cable to the earth ground
wire or connect the earth conductor to the appropriate terminal
identified by the symbol
• P roduct including a battery : there is a risk of explosion if the battery
is replaced by an incorrect type of battery. Dispose waste battery
according the instructions.
• The instruction book of this product is available by contacting
the after-sales service.