Voltage range
LED nominal voltage
LED-tolerances
ELV-indication LED
Response time
LCD Range
LCD Resolution
LCD Accuracy
LCD Overrange indication
Safety current
Peak current
Measurement duty
Internal battery consumption
Single-pole phase test voltage range
Phase rotation test
Continuity test
Battery
Resistance measurement
Frequency measurement
RCD test
Temperature
Humidity
Altitude
Overvoltage
Standard
Protection
12
www.nieaf-smitt.com
EazyVolt Pro LCD
1...1000 VAC (16...800 Hz), 1...1500 VDC
6/12/24/50/120/230/400/690 V
(shown as LCD segments)
EN 61243-3
>50 VAC, >120 VDC
<1 at 100 % of each nominal value
1...1000 VAC (16...800 Hz), 1...1500 VDC
0.1 V (1...29.9 V), 1 V (30...1500 V)
±3 % ±5 dgt (1...29.9 V)
±3 % ±3 dgt (30...1500 V)
'OL'
Is < 3.5 mA (at 1000 V)
<3.5 mA (at 1000 V)
30 s ON (operation time <690 V),
10 s ON (operation time >690 V),
240 s OFF (recovery time)
Approx. 120 mA
100...1000 VAC (50/60 Hz )
170...1000 V phase-to-phase,
AC (40-70 Hz)
0...500 kΩ + 50 %
3 V (IEC LR03 1.5 V x 2)
0...1999 Ω; accuracy: 5 % ±10 dgt @
25
C; resolution: 1 Ω
o
1...800 Hz; accuracy: ±5 % ±5 dgt;
resolution: 1 Hz
~ 30 mA @ 230 V
-15 °C...55 °C operation;
-20 °C...70 °C storage;
No condensation
Max 85 % RH
up to 2000 m
CAT IV/600 V / CAT III/690 V
EN/IEC 61243-3:2014
IP 64