Frequency test (Pro LCD only)
Switch into frequency measurement by short pressing 4 times
the
button or repeat short pressing until Hz symbol is
shown on LCD. Fr and Hz symbol should be on LCD. Connect
both test probes to the AC voltage under test. Frequency from
1 Hz to 800 Hz can be shown on LCD
Frequency measurement is possible for voltages >10 VAC
The level of voltage will be shown only on the bar graph
7.14

Self test

LEDs up to 50 V (Pro LED), all LCD segments and vibration
motor (Pro LCD), torch light, ELV indication and buzzer are
turned on for a second after battery replacement or selftest
activation
Selftest can be activated:
Shorting L1(-) and L2(+) probe tips while device is turned
OFF – leave device OFF for 30 seconds before shortening tips
7.15

NCV Test (Pro LCD only)

Switch into NCV measurement by short pressing 5 times the
button. LCD will show NCV symbol
The NCV function is used to verify that the wire is energized
Hold the voltage tester with the sensor against the wire or
cable. The voltage tester indicates the strength of the signal
digitally on the LCD screen
7.16

HOLD Function (Pro LCD only)

Long press (2 seconds) on
and freezes display value. With short press on 'torchlight/
function' button freezing of display is released. When HOLD
function is active
7.17

Backlight (Pro LCD only)

White Backlight is on all the time while tester is turned on
Backlight will be green when voltage <50 VAC or <120 VDC
Backlight will be red when voltages >50 VAC or >120 VDC and
for single pole detection
7.18

Battery Replacement

Remove the probes from any testing point, when opening the
battery case. Batteries are dead when the continuity test with
both test probes connected cannot be done anymore.
Follow the procedure below and replace batteries with new ones
(type IEC LR03 1.5 V).
Unscrew the battery door
Pull out the battery door and replace the batteries
Insert new batteries according to the printing on the battery
door
Re-assemble battery door.
Confirm that the battery door case is properly locked prior to
measurements
8

Cleaning and storage

Tester does not need any special maintenance if used according
to user manual.
Remove tester from all test points before cleaning.
Use a lightly damp cloth with neutral detergent for cleaning the
instrument. Do not use abrasives or solvents.
Do not expose the instrument to direct sun light, high tempera-
ture and humidity or dewfall.
Remove batteries when the instrument will not be in use for a
long period.
9

Maintenance

Unauthorized persons shall not disassemble the tester and the
supplementary equipment
When using testers in compliance with the instruction manu al,
no particular maintenance is required