UK │ 2. Scope of delivery
2. Scope of delivery
Thermostat TH 10 incl. temperature sensor
(2 m connection cable) and these mounting
instructions.

3. Specialist installer qualification

The thermostat may only be installed by a
trained electrician, in line with these
instructions. You are deemed competent if
you can competently and safely connect units
to an electrical power supply in line with the
wiring diagram, on the basis of your technical
training and experience and are able to
recognise and avoid risks and dangers
associated with electricity.
4. Intended use
This thermostat is used for controlling fans
depending on the air temperature. For indoor
deployment. The thermostat is only intended
for domestic use and similar purposes.
5. Non-intended use
DANGER
Explosion hazard if operated in an
explosive atmosphere in the case of
ignition, e.g. from sparks.
Never use the thermostat in an explosive
atmosphere.
NOTICE
Unit damage through modifications and
alterations. Modifications and alterations
to the unit are not permitted and release the
manufacturer from any guarantee and
liability.
NOTICE
Damage to the unit when used outdoors.
Only use the thermostat in an indoor
location.
6

6. Safety instructions

WARNING
Risks for people (including
children) with reduced
physical, sensory or mental
capabilities or a lack of
knowledge.
Thermostat may only be
installed, commissioned,
cleaned and maintained by
people who can safely
recognise and avoid the risks
associated with this work.
DANGER
Danger from electric shock.
Before accessing the
connection terminals:
Switch off all supply circuits.
Cover or block off neigh-
bouring live components
Protect against being acci-
dentally switched back on
Check that there is in fact
no voltage present.

7. Function/Operation

When a setpoint temperature is reached, the
thermostat switches one or more fans on or
off, depending on the settings of the jumpers,
in the case of an increasing or a decreasing
air temperature (cooling/heating).
The setpoint temperature can be set using
the rotary knob [11]. The differential gap
between the on/off temperature is determined
with potentiometer [8].