Dc Current Measurements - BizLine BIZ 780 312 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN

5-4. DC Current Measurements

CAUTION : Do not make 10A current measurements for longer than 30
seconds. Exceeding 30 seconds may cause damage to the meter and/or the
test leads.
1.
Insert the black test lead banana plug into the negative COM jack.
2.
For current measurements up to 6000µA DC, set the function switch to the
mA jack.
3.
For current measurements up to 600mA DC, set the function switch to the
mA jack.
4.
For current measurements up to 10A DC, set the function switch to the
banana plug into the 10A jack.
5.
Press the MODE button to indicate "DC" on the
display.
6.
Remove power from the circuit under test, then
open up the circuit at the point where you wish to
measure current.
7.
Touch the black test probe tip to the negative side
of the circuit.
8.
Touch the red test probe tip to the positive side
of the circuit.
9.
Apply power to the circuit.
10.
Read the current in the display.
10
e_Notice_BIZ780312_EN-FR-NL.indd 10
µA/HZ/% position and insert the red test lead banana plug into the µA/
mA/HZ/% position and insert the red test lead banana plug into the µA/
10A/HZ/% position and insert the red test lead
15/05/2019 17:3

Publicité

Table des Matières
loading

Table des Matières