● Observe safety tips for refrigeration systems. There is a risk of injury.
● Dispose of the apparatus and the refrigerant properly. Observe the national
regulations.
● Refrigerant may not be allowed to get into sewers, basements or work pits.
Refrigerant vapours may create a suffocating atmosphere.
● Do not insert any objects into the apparatus. There is a danger of injury and
a risk of electric shock.
● Do not place any objects on the apparatus. Vibration of the apparatus can
cause the objects to fall off. The objects could be damaged. There is a risk of
injury.
● When installing the device, ensure adequate ventilation and the permissible
minimum room size of 9 m
ROLLER'S Scirocco 80 and a minimum distance of approx. 200 mm from
the wall. Never cover up the air vents of the apparatus. This can reduce the
performance. The apparatus can overheat. There is a danger of fi re.
● Do not use the apparatus in air-tight rooms. The apparatus can overheat.
There is a danger of fi re.
● Do not use highly infl ammable materials e. g. gases, oils as well as aerosol
cans with propellant gas, e.g. thread cutting oil, paints in the vicinity of the
apparatus. The device could be damaged. There is a danger of fi re.
● Never place the device in fl ooded rooms. Never lay the power cable and
extension leads on a damp or wet surface. There is a danger of electric shock.
● Always stand the apparatus properly upright on the wheels, even during
storage and transport. The apparatus could otherwise be damaged.
● Do not use the collected condensation (water) as drinking water or for
preparing meals. There is a risk to your health.
● Do not use the device if it is damaged. There is a danger of accident.
● Check the proper drainage of the condensation regularly. Switch off the
device during longer work breaks, pull out the mains plug and remove all
hoses. Electrical devices can cause hazards which lead to material damage or
injury when left unattended.
● Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the electrical
device safely may not use this electrical device without supervision or
instruction by a responsible person. Otherwise there is a risk of operating
errors and injuries.
● Only allow trained persons to use the electrical device. Apprentices may
only operate the electrical device when they are older than 16, when this is
necessary for their training and under the supervision of a trained operative.
● Check the power cable of the electrical device and the extension leads
regularly for damage. Have these renewed by qualifi ed experts or an authorised
ROLLER customer service workshop in case of damage.
● Only use approved and appropriately marked extension leads with a suffi -
cient cable cross-section. Use extension leads up to a length of 10 m with
cable cross-section 1.5 mm², from 10 – 30 m with cable cross-section 2.5 mm².
Explanation of symbols
WARNING
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
NOTICE
Material damage, no safety note! No danger of injury.
Warning against infl ammable materials
See the operating manual
Instructions for use; operating instructions
Service display; consult the operating manual
Use hand protection
Power tool complies with protection class I
Environmentally friendly disposal
CE conformity mark
Not suitable for using outdoors
12
for ROLLER'S Scirocco 50 and 14 m
2

1. Technical Data

Use for the intended purpose
WARNING
WARNING
The ROLLER'S Scirocco 50 and
ROLLER'S Scirocco 50 and
ROLLER'S Scirocco 50
building driers are intended for drying and dehumidifying rooms, e.g. after mains
water damage, fl ooding, dehumidifi cation of damp cellar rooms etc. and for fast
drying of concrete, masonry, plaster and screed for example. The operating hours
counter and electricity meter is intended for recording the operating hours and
electricity consumption when drying and dehumidifying with ROLLER'S Scirocco
50. For commercial use in trade and industry. All other uses are not for the intended
for
2
purpose and are therefore prohibited.

1.1. Scope of Supply

ROLLER'S Scirocco 50, 7.7 l condensation tank, condensation draining hose,
operating instructions.
ROLLER'S Scirocco 80, operating instructions.
1.2. Article numbers
ROLLER'S Scirocco 50 Set
ROLLER'S Scirocco 80 Set
11.5 l condensation tank Scirocco 80
Connecting fl ange Scirocco 80
Scirocco 80
Scirocco 80
Exhaust air hose Ø 200 mm, 10 m long, Scirocco 80
Exhaust air set Scirocco 80 (connecting fl ange,
Scirocco 80 (connecting fl ange,
Scirocco 80
exhaust air hose Ø 200 mm)
Condensation tank with pump Scirocco 50
Condensation tank with pump Scirocco 80
Operating hours counter and electricity meter
ROLLER'S Control W, dielectric humidity meter
Machine cleaner

1.3. Applications

Dehumidifi cation rate
Air volume
Adjustment range of
the relative humidity
Compressor
Ambient temperature
Storage temperature

1.4. Electrical data

See the rating plate!
Dehumidifi er/building dryer with R-410A / R-407C refrigerant
220 240 V~; 50 Hz
220 –
220 –
240 V~; 50 Hz
240 V~; 50 Hz
Dehumidifi er/building dryer with R-290 refrigerant
Condensation tank with pump
Operating hours counter and electricity meter
1.5. Coolant data
See the rating plate!
Coolant
Coolant
Coolant
GWP
CO
comp.
2
Filling quantity
Filling quantity
Filling quantity
Operating pressure low pressure side
Operating pressure high pressure side ≤ 36 bar
Coolant
Coolant
Coolant
GWP
CO
comp.
2
Filling quantity
Filling quantity
Filling quantity
Operating pressure low pressure side
Operating pressure high pressure side ≤ 24 bar
1.6. Dimensions L × W × H
ROLLER'S Scirocco 80
ROLLER'S Scirocco 80 electric air dehumidifi ers/
ROLLER'S Scirocco 80 electric air dehumidifi ers/
Scirocco 80
Scirocco 80
Scirocco 80
Scirocco 80
Scirocco 50
≤ 50 l/24 h
≤ 233 m
/h
/h
3
3
3
30 – 90 %
Rotation piston compressor Rotation piston compressor
+5 °C – +32 °C
(41 °F – 89 °F)
+5° C – +45 °C
(41 °F – 113 °F)
220 240 V~; 50 Hz
220 –
220 –
900 W; 4.1 A
Protection class I
220 – 240 V~; 50 Hz
220 – 240 V~; 50 Hz
760 W; 3.5 A
Protection class I
100 240 V~; 50 –
100 –
100 –
240 V~; 50 –
240 V~; 50 60 Hz
60 Hz
60 Hz
100 –
100 –
100 240 V~; 50 –
12 V – ---
---
---
230 V~; 50 Hz
≤ 3680 W
Protection class I
Protection class IP20
Protection class IP20
Protection class
4,5 V – ---
R-410A
R-410A
2088
0,6682 t
0.320 kg
0.320 kg
≤ 18 bar
R-290
R-290
3
0.0006 t
0.182 kg
0.182 kg
≤ 12 bar
385 × 320 × 595 mm
540 × 530 × 1 040 mm
(15,2" × 12,6" × 23,4")
(21,3" × 20,9" × 40,9")
eng
132011
132010
132100
132100
132101
132101
132102
132102
132104
132129
132121
132132
132115
140119
Scirocco 80
≤ 80 l / 24 h
≤ 850 m
/h
/h
3
3
3
30 – 90 %
+5 °C – +32 °C
(41 °F – 89 °F)
+5° C – +45 °C
(41 °F – 113 °F)
1200 W; 5.3 A
Protection class I
680 W; 3.0 A
Protection class I
240 V~; 50 60 Hz
240 V~; 50 –
– ---
12 V
12 V
R-407C
R-407C
1774
1,455 t
0.820 kg
0.820 kg
≤ 10 bar
≤ 25 bar
R-290
R-290
3
0.0009 t
0.300 kg
0.300 kg
≤ 10 bar
≤ 22 bar

Publicité