In T cell
Stick the vase of the cell and then takes up electrodes, the water tightness seal, grease before, and
hand tighten the nut.
Insert the cell in its vase and positioning electrodes perpendicularly in water flow direction.
Use, if it is necessary, supplied 60/50 reducers.
In case of connection on flexible tubing, stick one by one the fitting on the 63/40 mm reducers and then
stick the set on the supplied D63 collars.
Wait that all the stickings are totally dry before handing pipes under pressure.
Connect the cell supply cable to the controller box:
Position the 2 terminals (Brown and Blue) indifferently on one of the borders of cell.
Install the lock washers and the nuts, and then tighten nuts (using a size 10 spanner), gently, until the
blocking.
Put safety lids on theses connectors.
Incorrectly connected cell entails dommages even going so far to destruction. Guarantee doesn't be
used in this case.
PH PROBE AND INJECTION SYSTEM
4
Connect the suction strainer to the pH pump with a part of the supplied pipe. Respect the sense of
arrows representing on the top of the pH pump.
Screw the injection connector under the accessories holder and connect the exit of the pH pump to the
injection connector with the rest of the supplied pipe.
Screw the probe holder on the accessories holder with Teflon. Remove the rubber protection at the
end of the pH probe. Screw the probe on the top of the accessories holder (make sure that it is not in
abutment with the waterworks).
Connect the cable of the pH probe (BNC jack) under the controller box.
DUO AQUALUX – PAPI004070 – FR – EN – DE – Rev.03.16
Note : Do not put the corrective tin directly under the device
An incorrect positioning of
the injection connector can
entail the deterioration of
the pump.
7