Technical data

Type
Input pressure [bar]
Output
pressure
Operating medium
Installation position
Ambient
temperature
Weight
1) If the regulator spring is at maximum tension (rotary knob turned all the way clock
wise), the maximum output pressure can be exceeded by 40 %:
Max. 14 bar on DPA− −10
Max. 22 bar on DPA− −16
26
DPA−40
−10
2.5
8
[bar]
4.5
1)
10
Filtered compressed air, non−lubricated, grade of filtration
40 m
as desired
[°C]
+5
+60
[kg]
1.5
DPA−63
−16
−D
−10
−16
2.5
2.5
2
2
10
8
8
10
4.5
5
4
4
16
16
10
16
6.0
DPA−100
−D
−10
−16
−D
2
2
2
2
8
8
10
8
4
4
4
4
16
10
16
16
13.0