5
Installation
Mechanical
Note
The DPA must not be installed on the controller thread because the controller
thread may be destroyed under the load of the DPA.
Fasten the DPA in one of the following ways only:
Type
Fastening method
DPA−40
Direct fastening
With FDPA−40
flange mounting
accessory
DPA−63/100 Direct fastening
With HUA foot
mounting acces
sory (2x)
1) The exhaust hole and both valve exhaust ports (6/7 è Fig. 1) must not be sealed.
18
1)
with 4 screws (M4) in
the threaded holes of the
DPA. Tightening torque
2 Nm.
Flange with 4 screws
(M4) in the threaded
holes of the DPA.
Tightening torque 2 Nm.
Fit the flange to the wall
with 2 screws (M5).
With 4 screws (M10) in
the threaded holes of
the DPA. Tightening
torque 30 Nm.
Foot mounting, with two
screws each in the
threaded holes of the
DPA on the right and left.
Tightening torque 30 Nm.