SAFETY MEASURES
Read carefully the operating instructions
before assembling and starting. The ap-
pliance must not be used by persons who
are not thoroughly acquainted with the
instructions handbook (operating instruc-
tions). Children and persons under the age
of 16 cannot use the pump and must be
kept well away from the appliance when
it is connected. The user is liable towards
third parties in the area where the appli-
ance is in operation.
While the pump is operating, persons must
not be in the liquid to be pumped. The pump
may be connected only by means of a safe-
ty switch for fault currents, with a rated
opening current up to 30 mA and a socket
with an earth contact installed in conformi-
ty with the regulations.
Protection: at least 10 Amps.
Operation in swimming pools and garden
ponds is admitted.
CAUTION: Before checking, connect the
pump and the system with no voltage!
Replacing the line connecting up with the mains
requires using special tools and therefore may be
done only by the manufacturer or its service en-
gineers. The pump may operate only with a pipe
connecting the appliance (extension) that is no
lighter than a rubber hose mod. H07 RNF in con-
formity with the DIN57282 or DIN 57245 standard.
(For your safety)
The voltage (230 Volts alternating current) indi-
cated on the pump's rating plate must correspond
to the available mains voltage. Before starting it is
necessary to make sure by having a check made by
qualified personnel that there are the necessary
electrical protection measures.
Earth connection.
f
Earthed neutral.
f
The safety switch for fault currents corresponds
f
to the safety regulations of the electricity board
and functions perfectly.
Plug connections must be protected from water.
f
If there is a risk of flooding, plug connections must
f
be placed somewhere safe.
Definitely avoid pumping aggressive liquids and
f
abrasive products. In the event of the pump fail-
ing, repair work may only be carried out by the
repair workshops of the technical service.
Only genuine spare parts must be used.
f
It is notified that in conformity with the law on
f
product liability we cannot be held responsible
for the damage caused by our appliance:
1. because of improper repairs not carried out by
the personnel of the assistance points autho-
rized by us;
2. or if GENUINE SPARE PARTS are not used to
replace parts;
3. or if the indications and provisions given in the
instructions handbook are not complied with.
The same provisions hold for the accessories.
RESISTANCE
The maximum temperature of the delivery
liquid should never exceed +35°C in continuous
operation. Inflammable, combustible or explosive
liquids cannot be conveyed with this pump!
In particular, do not use engine fuels, detergents,
or other chemical products.
USE
CAUTION: Sector of use
1) DRAINAGE PUMP: To transfer and
empty fresh to slightly polluted water
from rainwater barrels and casks.
2) VORTEX: To transfer water with solids in sus-
pension. Also used as emergency pump, in case
of over-flowing with muddy water, thanks to its
large suction filter.
To achieve excellent motor cooling the pump cas-
ing is provided with a breather hole that enables
water to flow out. The pump must be protected
from running dry.
STARTING
First put the pump into water and then connect
the plug. The pump is ready for use.
BEFORE STARTING
Installation of your canned motor pump is:
fixed with a fixed pipe, or
f
fixed with a flexible hose.
f
TAKE CARE
When installing it is necessary to take care that
the pump is always placed in a raised position
with respect to the bottom of the well so that the
muddy bottom is not sucked up with the water.
Never handle or hang the pump by gripping the
power supply cable.
In pumps with a floating switch, the latter is
adjusted in order to make immediate starting
possible.
NOTE:
The pump well must have minimum dimensions
of 40x40x50 cm so that the floating switch can
move freely. It is also possible to use round,
prefabricated concrete wells with an inner
diameter of approx. 40cm.
MAINTENANCE INSTRUCTIONS
Your canned motor pump is a quality product, free
from maintenance. It has been subjected to rigorous
final checks. However, for a long service life and con-
tinuous operation, we recommend constant care
and regular checks:
Before every maintenance job, disconnect the
ƒ
plug.
For transportable use the pump should be washed
ƒ
with clear water after every use.
For fixed installation it is recommended to check
ƒ
the operation of the floating switch every 3

Publicité