5.
hydraulic connections
balneo
front
pannel
6.
electric connections
This must be done by a qualified technician.
- Check that the voltage corresponds to the equipment supplied.
- With a Piezo electric control, there is no maximum distance.
- Connect the electrovalve
7.
operation
Once the baleno and the CCS has been installed, check the direction of rotation of the pump motor (for a
3-phase pump).
valve
pump discharge
valve
pump suction
to the grey output.
Please refer to the electric box diagram.
REMOTE CONTROL
•
•
•
electrovalve
valve
valve
Remote control synchronization: During the 15 seconds of
powering up the case, press and hold keys A and B simultaneously
Use : Button A: ON/OFF Pump
Operation :
₀
First push on the remote or one of the two push-button, the
pump starts.
₀
Second push, the electrovalve change position after 15''.
₀
Third push, the pump stop and the 3-way electrovalve return
in its initial position.
14
CCS
front
pannel
N