Constant pump operation
With this function, selected pump
is in constant operation. The func-
tion is disconnected in the factory
setting. This function limits the hot
water supply, particularly when there
is little need of heat.
1.
Press the button with the arrow
until the Menu symbol flashes.
Press +On.
Automatic temp. increase
At 02.00 hours (night time) the boiler
starts and works in accordance with
Warm water (item 5) if the clock is
set. The reason for this is to reduce
the risk of legionella.
The function is disconnected in
the factory setting.
1.
Press the button with the arrow
until the Menu symbol flashes.
Press +On.
19.
Fault messages
In case an error occurs in the system, the display will show the reasons for it (applies only when the boiler
is at rest)
BATT LO: If the vehicle, boat or building has a battery voltage below 10,5 V, the boiler will stop. The heater is
automatically reset when the voltage comes up to 11V.
FAN: Faulty fan speed. Automatic resetting after 5 minutes.
GAS OUT: Gas finished. Resetting by switching off and restarting the boiler in accordance with item 1.
OHEAT 1: Thermostat (blue cable) released. To reset, disconnect 12V from the boiler and connect again.
OHEAT 2: Overheating protection (red cable) released. To reset, disconnect 12V from the boiler and
connect again.
WINDO: Window open, the boiler stops for gas. Gas operation in the boiler starts when the window is closed.
Electrical operation functions. Check in the instructions for vehicle, boat or building, if this
function has been installed.
SERIAL: There is a connection fault between boiler and panel. Normally, this is a mechanical fault in the
connection between the heater and panel. To re-set, break the main current and then start again.
top
•
Short circuit in the sensor in the control panel or in the remote sensor.
•
The outdoor sensor might have been incorrectly connected.
bot
•
Short circuit in outdoor sensor.
20.
Emergency start
•
Disconnect 12V and the cable to the panel on the heater.
•
Connect a cable between 2 and 9 in the contact device (on the heater).
•
Connect 12V to the heater.
Now the heater starts with gas and 1kW. (Regulation of room temperature does not function, constant pump
operation).
20
2.
When OF is displayed, step with
the arrow key until PE is dis-
played. Press +/On and constant
pump operation is connected.
blinkar
flashes
2.
When OF is displayed, step with
the arrow key until LE is dis-
played. Press +/On and legionel-
la is connected.
blinkar
flashes
3.
Press -/Off to disconnect con-
stant pump operation. Then press
Store to leave the pump operation
function.
blinkar
flashes
3.
Press -/Off to disconnect legionel-
la. Then press Store to leave the
legionella function.
blinkar
flashes