The device does not require any maintenance. If cleaning is required, use a dry cloth and follow the
procedure explained below.
CLEANING FUNCTION
This function makes it possible to temporarily inhibit the sensors so the glass plate can be cleaned
without accidentally sending any BUS commands. The function can be enabled/disabled as follows.
Enabling:
1. touch the plate as shown in figure B for at least 10 seconds, without touching the device chan-
nels
2. wait until you hear a long beep, then release
3. wait until all six LEDs are briefly flashing blue
4. start of inhibition time countdown, signalled by the activation of the blue LEDs in the following
sequence:
Disabling:
1. wait until the end of the inhibition time (30 s)
2. wait until you hear a long beep
3. wait until all six LEDs are briefly flashing blue
4. wait until the flashing stops and the current status signalling or night-time localisation is re-
stored.
During this function activation phase, the messages from the BUS are ignored (they will be man-
aged after you have quit the configuration phase).
Behaviour on BUS voltage failure and reset
If the BUS supply fails, the device will not carry out any action.
The start-up of the device (with the plate fitted) following a BUS failure is indicated by the sequential
activation of all six LEDs - redgreenblue.
This manual explains how to set the device parameters. All the information concerning the technical
data of the product, the connection diagrams, the descriptions of the commands, and the instruc-
tions for correct assembly are contained in the installation manual supplied with the product and
which can also be downloaded from the website www.gewiss.com.
INSTALLATION
Maintenance
LED 1 with LED 2 for 500ms
LED 3 with LED 4 for 500ms
LED 5 with LED 6 for 500ms
Initial start-up
19