4-Wire Cable from Power Supply
IMPORTANT: Use the 4-wire cable from power supply where
local codes do not permit connecting the frame-ground
conductor to the neutral (white) junction box wire.
A
B
C
D
A. Cable from power supply
B. Red wires
C. Green (or bare) ground wires
D. 4-wire flexible cable from range
E. Junction box
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the 4-wire flexible cable from the range to the
junction box using a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector if present.
5. Connect the 2 black wires together using the UL listed wire
connectors.
6. Connect the 2 white wires together using the UL listed wire
connectors.
7. Connect the green or bare ground wire from the range cable
to the green or bare grounded wire (in the junction box) using
the UL listed wire connectors.
8. Install junction box cover.
9. Reconnect power.
10
E
F
G
H
I
F. White wires
G. UL listed wire connectors
H. Black wires
I. UL listed or CSA approved
conduit connector
3-Wire Cable from Power Supply
IMPORTANT: Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground conductor to
the neutral (white) junction box wire (not used for Canadian
installations).
A
B
C
D
E
F
G
A. Cable from power supply
B. Junction box
C. Red wires
D. White wire (from power supply)
E. Green (or bare) grounding wires
(from range)
F. White wire (from range)
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the 4-wire flexible cable from the range to the
junction box using a UL listed or CSA approved conduit
connector.
4. Tighten screws on conduit connector if present.
5. Connect the 2 black wires together using UL listed wire
connectors.
6. Connect the 2 red wires together using UL listed wire
connectors.
7. Connect the green (or bare) and white range cable wires to
the white (neutral) wire in the junction box using UL listed
wire connectors.
8. Install junction box cover.
9. Reconnect power.
Attach Backguard or Island Trim
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Using 2 or more people, move range close to cabinet
opening.
2. Remove cardboard or hardboard from under range. Move
range into it's final location.
3. Attach the backguard or island trim as required for your
installation. See "Tools and Parts." Attachment screws are
included in the literature package.
H
I
J
G. 4-wire flexible cable from
range
H. Black wires
I. UL listed wire connectors
J. UL listed or CSA
approved conduit
connector