Attach Backguard Or Island Trim; Make Gas Connection - KitchenAid YKDRP707 Instructions D'installation

Masquer les pouces Voir aussi pour YKDRP707:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Using the final measurement from Step 3, measure from the
floor up and mark a horizontal line on the wall where a wall
stud is located.
A
D
A. Horizontal line marked from Step 4.
B. Wall stud
C. Mounting screws
D. Anti-tip bracket
5. Position top of anti-tip bracket at line marked in Step 4 and
mark holes. Drill two ¹⁄₈" holes at the positions marked on the
wall. Use screws provided to fasten anti-tip bracket to wall.
Anti-tip bracket must be mounted securely to stud in wall
behind the range. Depending on thickness of the wall, longer
screws may be required. Longer screws are available from
your local hardware store.

Attach Backguard or Island Trim

WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
1. Using 2 or more people, move range close to cabinet
opening.
2. Remove cardboard or hardboard from under range. Move
range into final position.
3. Attach the backguard or island trim as required for your
installation. See "Tools and Parts." Attachment screws are
included in the literature package.
Attaching the Backguard
36" (91.4 cm) model shown
A. 3 front screws (4 rear screws required but not shown)
10
All manuals and user guides at all-guides.com
B
C
A
Attaching the Island Trim
36" (91.4) model shown
A. Center hole not used
4. Using 2 or more people, tip the range back so that the front
feet lift off the ground. Slide range toward the wall until the
rear brace is under the anti-tip bracket. Stand range up,
making sure the anti-tip bracket catches the rear brace.

Make Gas Connection

1. Assemble flexible connector from gas supply pipe to pressure
regulator located in the middle front of the range.
2. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in following illustration).
3. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
4. Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A
B C
A. Gas pressure regulator
B. Use pipe-joint compound
C. Adapter (must have ½" male
pipe thread)
D. Flexible connector
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
A
D
E
H
G
F
E. Manual gas shutoff valve
F. ½" or ¾" gas pipe
G. Use pipe-joint compound
H. Adapter
B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ykdrp767

Table des Matières