Water Level Adjustment

Water level can be adjusted means of height adjustment of the floater.
For this purpose lift up the locking screw (1).  Open the cover (2). Loose the hexagon nut (102.0621) (3), adjust the floater at desired height (3) and
tighten the nut on again. Close the cover. Click into place the locking screw.
Take care of the following:
Float valve has to be placed that way that it is situated in a 90° angle to the valve lever (102.0393).
Water pressure max. 5 bar (73 psi)
1
19.11.2018 · Technische Änderungen vorbehalten · Technical data can be changed without prior notice · Des changements techniques reservés · Мы оставляем за собой право на технические изменения и
дополнения, а также возможные опечатки. · 1048152
Water Level Adjustment
2
3
102.0393
Height adjustment
102.0621