ENGLISH
REARMING BALTIC AUTOMATIC VERSION
Unscrew the used capsule anticlockwise
1.
by the inflation mechanism. Replace the capsule if it has been activated or if it has passed its
expiry date
it must be replaced before February 2022.
Refit the examined capsule if ok if not screw in a new capsule clockwise and tighten it by hand
2.
until no threads are visible. The lower indicator window on the valve head should now be green.
Unscrew the CO
3.
manner. Check that the lever and the pin (visible at the bottom of the valve head next to the
CO
cylinder's fastening)
2
the lever and secure it by pressing it against the valve head until it clicks into place.
Visually check that the O-ring in the bottom of the valve head, next to the CO
4.
ning, is undamaged
Screw in a new, clean and unpierced CO
5.
Use no tools.
When both capsule and CO
REARMING BALTIC MANUAL VERSION
Unscrew the CO
1.
manner. Check that the lever and the piercing pin (visible at the bottom of the thread for the
CO
cylinder
2
secure it by pressing it against the valve head until it clicks into place.
12
Visually check that the O-ring in the bottom of the valve head, next to the CO
2.
ning, is undamaged
Screw in a new, clean and unpierced CO
3.
Use no tools.
When the CO
, which is stamped on the side of the capsule. For example, 02 2022 means
5
cylinder anticlockwise. Discard the cylinder in an environmentally friendly
2
can move freely, by pulling on the activating cord. Fold back
10
.
11
cylinder are mounted correctly, both indication windows should be green.
2
cylinder anticlockwise. Discard the cylinder in an environmentally friendly
2
10
can move freely, by pulling on the activating cord. Fold back the lever and
.
11
cylinder is mounted correctly, the indicator window should be green.
2
, Follow the illustrated instructions on the label
9
cylinder using only hand force until absolutely tight.
2
cylinder using only hand force until absolutely tight.
2
cylinder's faste-
2
cylinder's faste-
2